我们将在海王星Apex系列的第九集向您展示如何校准您的盐度探头。第一步:从容器中取出探针,吹出末端的水,让它干燥。我建议放几个小时让它完全干燥。这是非常重要的,在探针内的触点之间没有水分。第二步:点击电导率校准按钮(应该是干电导率探头,并设置一个数字)。步骤3。当数字停止移动10-20秒后,点击OK。提示:在此期间,将校准溶液漂浮在水箱或水槽中,使其与水箱的温度相同。步骤4:选择你正在校准的溶液。小贴士:绝大多数咸水水族馆的主人会使用53000溶液,即千分之三十五,或大约1.026的比重。 Step 5. Tear or clip the corner off the solution and insert probe. Hold the calibration solution with the probe in the tank so it maintained the same temp as your temperature probe (this is critical). Step 6: Ensure one of the air holes on the probe is turned upward. Give it a few light taps with your finger to get any air out, and wait for the settling number to stop changing for 10-20 seconds. Try tapping the probe again to see if there is any air left - if the number doesn't change, hit OK. TIP: The probe is fragile, so be sure to have a light hand when it comes to tapping air out. Step 7: Confirm your probe is calibrated by leaving it in the solution and checking your home screen, it should read very closely to thirty five parts per thousand. Remember if you have any issues with this process, the first step is to remove the probe completely and isolate the cord from electrical noise. Throw the temp and salinity probe in the same cup to completely remove the stray voltage issue and see if the if the readings look reasonable now. If you have any questions about this process or tips for your fellow reefers check out the comments area down below. Make sure to hit subscribe to get future episodes in our Apex series! Check out the entire Apex line: http://brs.li/neptuneapex Watch the whole playlist: https://www.youtube.com/playlist?list=PLBaMLrfToJyz8091y-PoECoUo5QfMGg1S Connect with us on Facebook: http://www.facebook.com/BulkReefSupply Check out our pics on Instagram: http://instagram.com/bulkreefsupply